Hotel HOCl implementation checklist: confirm directions, plan precleaning and testing, and size an EWCO 300 or Hypo 7.5 for housekeeping work.

This checklist is a planning aid, not an approved housekeeping protocol, and makes no claim that any HOCL LLC or EWCO product is authorized for a particular hotel use.
The short answer
For hotels, on-site HOCl works best as a defined part of housekeeping: specific surfaces, written directions, trained staff, and records. Start by confirming that the product you'll use has directions for the surfaces and uses you intend. Then plan precleaning, contact time, compatibility, testing, and training.
Phase 1: Define uses and confirm directions
- ☐ List the surfaces and areas: guest-room high-touch surfaces, bathrooms, common areas, back-of-house, food areas.
- ☐ For each, identify the product and directions that cover that use. Food areas and surfaces that touch food are outside this checklist.
- ☐ Don't use generator output for hand or skin cleaning. Don't ingest it or apply it to the body.
- ☐ Fogging, misting, or other area-wide application: use only if the product's directions specifically cover it. The EWCO 300 manual cautions that small quantities of hydrogen, chlorine dioxide, and ozone can be released from electrolyzed water and that chlorine gas can form if pH becomes acidic. Get technical and regulatory review before any area-wide application.
Phase 2: Precleaning and application
- ☐ Clean first. Soil can keep a solution from reaching the surface.
- ☐ Contact time. Use the time in the directions, and keep the surface wet for the entire contact time.
- ☐ Ventilation and PPE: use good ventilation and any gloves or eye protection the directions recommend.
- ☐ Don't mix. Never mix HOCl solution with ammonia, bleach, strong acids or other cleaners; doing so can release toxic chlorine gas. Add only the ingredients and amounts your manual specifies. If someone breathes in fumes or swallows solution, call Poison Help at 1-800-222-1222 (poisonhelp.hrsa.gov).
Phase 3: Surface and material compatibility
- ☐ Check each surface and item manufacturer's care instructions: stone, wood, metals, fabrics, electronics.
- ☐ Check with the item or device manufacturer about compatibility with a chlorine solution. Chlorine solutions can corrode some metals and discolor fabrics, especially at higher concentrations. Don't assume HOCl solutions are compatible with every material.
- ☐ A spot test does not replace label or manufacturer approval.
Phase 4: Equipment, generation, and testing
- ☐ Size equipment to daily volume at the concentration your directions require. See Eco One vs Hypo 7.5 vs EWCO 300.
- ☐ Plan installation: the EWCO 300 manual requires a ventilated wall location, feed water hardness below 80 ppm, at least 1.5 L/min flow, and a trained operator; the Hypo 7.5 manual requires a well-ventilated area. The EWCO 300 makes up to 300 ppm. The Hypo 7.5 makes a 7.5 L (2 gal.) batch at 200 or 500 ppm. The Eco One (up to 500 ppm in a 1-liter batch) can also be used in a business setting for smaller areas.
- ☐ Test FAC and pH on each batch or at set intervals; readings are approximate and don't, on their own, show that directions have been met. See How to Test Generated HOCl: FAC and pH Checklist.
- ☐ Label containers. Store per the manual, out of reach of children. See Does HOCl Expire? Eco One Storage, Containers and Testing.
Phase 5: Training and records
- ☐ Train housekeeping staff on which surfaces, the directions, contact time, and what not to do.
- ☐ Designate a responsible person for the generator.
- ☐ Keep logs: generation date and time, FAC and pH readings, operator, and any issues.
- ☐ Review the program when products, surfaces, or procedures change.
What this doesn't replace
- Cleaning before you apply HOCl solution
- Product-specific directions for each use
- Hand-cleaning products
- Local regulations and your property's policies
Questions? Email service@hocl.com. Commercial applications: ewco.com.